{"id":198,"date":"2021-01-20T13:34:22","date_gmt":"2021-01-20T06:34:22","guid":{"rendered":"https:\/\/hm-techniek-432bfc.ingress-daribow.ewp.live\/?post_type=product&#038;p=198"},"modified":"2024-04-28T00:35:38","modified_gmt":"2024-04-28T00:35:38","slug":"compressor","status":"publish","type":"product","link":"https:\/\/hmtechniek.be\/?product=compressor","title":{"rendered":"Compresseur Inventer"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-2183\" src=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2024\/04\/IMG_5963-225x300.jpeg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2024\/04\/IMG_5963-225x300.jpeg 225w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2024\/04\/IMG_5963-768x1024.jpeg 768w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2024\/04\/IMG_5963-600x800.jpeg 600w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2024\/04\/IMG_5963-scaled.jpeg 1920w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/p>\n<p>Electronic Unit Specification<br \/>\n1. The electronic unit is a dual voltage device. This means that the same unit can be used in both 12V and 24V power supply systems, maximum voltage is 17V for a 12V system and 31.5V for a 24V system.<br \/>\nMaximum ambient temperature is 60C. The electronic unit has a built-in thermal protection which is actuated and stops compressor operation if the electronic unit temperature gets too high.<br \/>\n2. Installation (Fig.1)<br \/>\nConnect the terminal plug from the electronic unit to the compressor terminal. Mount the electronic unit on the compressor by snapping the cover over the screw head(1).<br \/>\n3. Power supply (Fig. 1)<br \/>\na. The electronic unit must always be connected directly to the battery poles(2), connect the plus to (+) and the minus to (-), otherwise the electronic unit will not work. The electronic unit is protected against reverse battery connection.<br \/>\nb. For protection of the installation, a fuse (3) must be mounted in the (+) cable as close to the battery as possible. 15A fuse for 12V and 7.5A fuse for 24V circuits are recommended for model QDZH25G, QDZH30G and QDZH35G; 30A fuse for 12V and 15A fuse for 24V circuits for model ODZH65G<br \/>\nc.If a main switch (4) is used, model ODZH25G, QDZH30G and QDZH35G should be rated to a current of min. 20A; model QDZH65G should be rated to a current of 40A @ 12V and 20V @ 24V.<br \/>\nd. The wire dimensions in Table. 2 must be observed. Avoid extra junctions in the power supply system to prevent voltage drop from affecting the battery protection setting.<br \/>\n4. Battery protection (Fig.1)<br \/>\na. The compressor is stopped and re-started again according to the decided voltage limits measured on the (+) and (-) terminals of the electronic unit.<br \/>\nb.The standard settings for 12V and 24V power supply systems appear from Table.3. Other setting (Table.1) are optional if a connection which includes a resistor (9) is established between terminals C and<br \/>\n5. Thermostat switch(Fig. 1)<br \/>\na. The thermostat (7) is connected between the terminals C and T. Without any resistor in the control circuit, the compressor with electronic unit will run with a fixed speed of 2000pm when the thermostat is switched on.<br \/>\nb.Other fixed compressor speeds in the range between 2000 and 3500pm can be obtained when a resistor (8) us installed to adjust the voltage (V) of the control circuit. Resistor values for various motor speeds appear from Table.4.<br \/>\n6.Fan (Optional, Fig. 1)<br \/>\na.A fan (5) can be connected between the therminals (+) and (F). Connect the plus to (+) and the minus to (F). Since the output voltage between the terminals (+) and (F) is always regulated to 12V, a 12V fan must be used for 12V and 24V power supply systems.<br \/>\nb. The fan output can supply a continous current of 0.5A. A higher current draw is allowed for 2 seconds during start.<br \/>\n7.LED(Optional, Fig. 1)<br \/>\na.A 10mA light emitting diode (LED)(6) can be connected between the terminals (+) and (D). b.In case the electronic unit records an operational error, the diods will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash will last 1\/5 second.<br \/>\nAfter the actual number of flashes there will be a delay with no flashes, so that the sequence for each error recording is repeated every 3 minutes.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-2159\" src=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-225940-221x300.png\" alt=\"\" width=\"221\" height=\"300\" srcset=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-225940-221x300.png 221w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-225940.png 396w\" sizes=\"(max-width: 221px) 100vw, 221px\" \/> <img decoding=\"async\" class=\"alignnone size-medium wp-image-2160\" src=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230001-204x300.png\" alt=\"\" width=\"204\" height=\"300\" srcset=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230001-204x300.png 204w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230001.png 401w\" sizes=\"(max-width: 204px) 100vw, 204px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-2161\" src=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230020-184x300.png\" alt=\"\" width=\"184\" height=\"300\" srcset=\"https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230020-184x300.png 184w, https:\/\/hmtechniek.be\/wp-content\/uploads\/2021\/01\/Capture-decran-2024-04-24-230020.png 398w\" sizes=\"(max-width: 184px) 100vw, 184px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<ul class=\"ul-style check\">\n<li>Study history up to 30 days<\/li>\n<li>Up to 5 users simultaneously<\/li>\n<li>Has HEALTH certificate<\/li>\n<\/ul>\n","protected":false},"featured_media":2183,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[16,154],"product_tag":[155],"class_list":["post-198","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","product_cat-compressor","product_tag-compressor-frigo","ts_product_brand-hmtechniek","first","instock","sale","shipping-taxable","purchasable","product-type-simple","add-to-wishlist-after_add_to_cart"],"_links":{"self":[{"href":"https:\/\/hmtechniek.be\/index.php?rest_route=\/wp\/v2\/product\/198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hmtechniek.be\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hmtechniek.be\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hmtechniek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=198"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hmtechniek.be\/index.php?rest_route=\/wp\/v2\/media\/2183"}],"wp:attachment":[{"href":"https:\/\/hmtechniek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=198"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/hmtechniek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=198"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hmtechniek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=198"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hmtechniek.be\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}